HomeKohlerKohler COM 7.5

Kohler COM 7.5 Generator Set

The Kohler COM 7.5 is a 7.5 kW Natural Gas or Propane standby generator set powered by a Kohler CH-20 engine. It holds about 1.9 L (0.5 gal) of oil.

7 kW
Standby
0.624 L
Displacement
1.9 L
Oil capacity
4
Document types

How to read your Kohler serial & model number →

Specifications

FuelNatural Gas or Propane
Standby power7 kW
Controllermicroprocessor
Oil capacity1.9 L

Engine

Kohler CH-20
Oil capacity1.9 L
Displacement0.624 L
Aspirationair-cooled
Rated speed3600 rpm

Maintenance & consumables

for the Kohler CH-20
ItemSpecCapacityPart #Interval
Air filter24 083 02500 hr buy
Fuel filter find
Oil filter12 050 01500 hr Amazon eBay $19.49
OilSynthetic 5W-301.9 L100 hr

Common questions

What is the power rating of the Kohler COM 7.5?

The Kohler COM 7.5 is rated 7 kW standby.

What engine does the Kohler COM 7.5 use?

The Kohler COM 7.5 is powered by the Kohler CH-20 engine.

What fuel does the Kohler COM 7.5 use?

The Kohler COM 7.5 runs on Natural Gas or Propane.

What is the oil capacity of the Kohler COM 7.5?

The Kohler CH-20 engine in the Kohler COM 7.5 has an oil capacity of 1.9 liters.

Troubleshooting

3

Symptoms & remedies

SymptomRemedy
Accidental startingDisconnect the battery cables before working on the generator set. Remove the negative (--) lead first when disconnecting the battery. Reconnect the negative (--) lead last when reconnecting the battery.
Battery acid cleanupAdd 500 g (1 lb.) of bicarbonate of soda (baking soda) to a container with 4 L (1 gal.) of water and mix the neutralizing solution. Pour the neutralizing solution on the spilled battery acid and continue to add the neutralizing solution to the spilled battery acid until all evidence of a chemical reaction (foaming) has ceased. Flush the resulting liquid with water and dry the area.
Battery short circuitsDisconnect the battery before generator set installation or maintenance. Remove all jewelry before servicing the equipment. Use tools with insulated handles. Remove the negative (--) lead first when disconnecting the battery. Reconnect the negative (--) lead last when reconnecting the battery. Never connect the negative (--) battery cable to the positive (+) connection terminal of the starter solenoid. Do not test the battery condition by shorting the terminals together.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Fuel consumption

RatingLoadL/hgal/h

Available documents

ReferenceOwner's manualParts manualService manual